IBM FlashSystem Storage for Power 11: What Attaches Where
A Power 11 system has three distinct flash storage paths, and buyers who conflate them end up ordering the wrong hardware. Internal NVMe U.2 bays sit inside the chassis itself. The NED24 drawer extends that same direct-attached NVMe footprint externally, but still over a direct connection, not a SAN. IBM FlashSystem storage is the third path: an entirely separate, externally managed array that attaches over Fibre Channel SAN and can be shared with other platforms on the same fabric.
Direct-attached NVMe vs. SAN-attached FlashSystem
Power 11 flash storage paths compared
| Path | Attachment | Shared Across Platforms |
|---|---|---|
| Internal NVMe U.2 | Direct, inside chassis | No |
| NED24 expansion drawer | Direct, external cabling | No |
| IBM FlashSystem | Fibre Channel SAN | Yes, when configured for multi-host attachment |
FlashCore Module part numbers and feature codes
IBM FlashSystem arrays are populated with FlashCore Modules (FCM), IBM's NVMe drive that performs inline compression and encryption in the drive controller. Four generations have shipped to date, and the same nominal capacity within a generation can carry more than one valid part number depending on frame and drawer configuration.
IBM FlashCore Module part numbers and feature codes
| Generation | Capacity | Part Numbers | Feature Codes |
|---|---|---|---|
| FCM1 | 4.8 TB | 01YM582, 01YM482, 01EK233, 03LG613, 01YK819 | AES1, ADS1, AHS1 |
| FCM1 | 9.6 TB | 01YM583, 01YM943, 01YM493, 01EK232, 01YK818 | AES2, ADS2, AHS2 |
| FCM1 | 19.2 TB | 01YM584, 01EK231, 01YM501, 01YK817 | AES3, AHS3, ADS3 |
| FCM2 | 4.8 TB | 02YC416, 02YC423, 03GU599, 02CL186, 03GH469, 03GH824, 03GU518, 03GU531 | AES5, ADS5, AGS5, AHS5 |
| FCM2 | 9.6 TB | 03GU600, 02YC417, 03GH470, 03GH766 | AES6, ADS6, AGS6, AHS6 |
| FCM2 | 19.2 TB | 02YC418, 02CL183, 02CL182, 03GH471, 03GH764 | AES7, ADS7, AGS7, AHS7 |
| FCM2 | 38.4 TB | 02YC419, 03GH472 | AES8, AGS8, ADS8, AHS8 |
| FCM3 | 4.8 TB | 03JK076, 03JK162, 03GH935, 03GH936, 03JK687 | ADSA, AGSA, AHS9 |
| FCM3 | 9.6 TB | 03JK077, 03JK163, 03JL077, 03JK693, 03GH933, 03LG627 | ADSB, AGSB, AHSA |
| FCM3 | 19.2 TB | 03JK078, 03GH931, 03GH932, 03JK160, 03JK164, 03JK699 | ADSC, AGSC, AHSB |
| FCM3 | 38.4 TB | 03JK079, 03JK165 | ADSD, AGSD, AHSC |
| FCM4 | 4.8 TB | 03NK832, 03JK992 | ADSE, AGSE, AHSE |
| FCM4 | 9.6 TB | 03NK831, 03LG001, 03LG002, 03JN354 | ADSF, AGSF, AHSF |
| FCM4 | 19.2 TB | 03NK830, 03LG010 | ADSG, AHSG, AGSG |
| FCM4 | 38.4 TB | 03NK829, 03LG019 | ADSH, AGSH, AHSH |
A supported Fibre Channel host adapter is required on the Power 11 side for FlashSystem attachment. See PCIe Adapters for Power 11 for adapter options, and the IBM FlashSystem External Storage listing for the full compatibility and best-fit detail.
Sources
Related Models
IBM Power S1112 (9242-21B / 9242-21T)
The entry point into the IBM Power 11 generation: a single-socket, half-width 2U rack or tower system built for branch, edge, and smaller IBM i, AIX, and Linux deployments.
IBM Power S1122 (9824-22A)
A dense, dual-socket 2U scale-out server offering up to 60 Power 11 cores and 4 TB of DDR5 memory, IBM's mainstream choice for growing IBM i, AIX, and Linux environments.
IBM Power S1124 (9824-42A)
A quad-socket-capable, high-performance 4U scale-out server offering up to 60 Power 11 cores and 8 TB of DDR5 memory, built for enterprises and regional data centers.
IBM Power L1122 (9856-22H)
The Linux-optimized sibling of the S1122: a dual-socket 2U server with the same hardware ceiling but licensed for Linux-first environments, with limited AIX/IBM i core use.
More From the Library
- Power 11 S1112 for Healthcare AI: Local Inference and IBM i Continuity
- CPW and rPerf Explained: How to Actually Compare Power 11 Processor Options
- HMC v11 Requirements for Power 11: What Changed From 7063-CR1
- IBM i Licensing and Software Tiers on Power 11: P05, P10, P20, P30 Explained
- Power 11's On-Chip AI Acceleration: What Matrix Math Acceleration Actually Does