Storage Expansion

IBM NED24 NVMe Expansion Drawer

What the NED24 NVMe expansion drawer is, how many a Power 11 system can attach, and when a drawer is the right answer instead of larger internal drives or external FlashSystem storage.

The NED24 is IBM's NVMe expansion drawer for Power 11: direct-attached flash capacity that extends a system past the drive bays in its own chassis. It is the answer to a specific problem, which is a machine with plenty of processor and memory headroom that has run out of somewhere to put data. It is not a general-purpose storage tier and it is not a substitute for a SAN.

TypeDirect-attached NVMe expansion drawer
Attaches toPower 11 scale-out and enterprise systems
Drawers on a 2U system1 (S1122, L1122)
Drawers on a 4U system2 (S1124), 1 (L1124)
Drawers on enterpriseUp to 4 per node (E1150, E1180)
Not supported onS1112

How many NED24 drawers each Power 11 model takes

NED24 support across the Power 11 line

ModelMachine typeNED24 drawersInternal NVMe before expansion
S11129242-21B / 21TNot supported12.8 TB across 4 slots
S11229824-22A1122.4 TB (8x 15.3 TB) or 51.2 TB (8x 6.4 TB)
S11249824-42A2244.8 TB (16x 15.3 TB) or 102.4 TB (16x 6.4 TB)
L11229856-22H1122.4 TB (8x 15.3 TB) or 51.2 TB (8x 6.4 TB)
L11249856-42H1244.8 TB (16x 15.3 TB) or 102.4 TB (16x 6.4 TB)
E11509043-MRUUp to 4 per node153 TB (10x 15.3 TB) or 64 TB (16x 6.4 TB) per node
E11809080-HEUUp to 4 per node102.4 TB per node (16x 6.4 TB) or 30.6 TB (2x 15.3 TB)

The L1124 takes one NED24 where the otherwise-equivalent S1124 takes two. That is a real difference between two machine types that match on nearly everything else, and it is easy to miss when comparing them on a spec sheet.

Drawer, bigger drives, or external storage

Larger internal drives first

If the chassis is populated with 6.4 TB drives, moving to 15.3 TB roughly triples internal capacity with no drawer, no rack space and no extra cabling. Check what is actually installed before pricing expansion ... plenty of systems are nowhere near their internal ceiling.

A NED24 when you need raw local flash

The drawer earns its place when internal bays are genuinely full and the workload wants direct-attached NVMe latency rather than a fabric hop. It adds capacity to one system, which is both the point and the limitation.

FlashSystem when more than one machine needs it

External FlashSystem storage costs more to introduce and gives you shared capacity, snapshots, replication and a data services layer that a direct-attached drawer does not have. If a second system will ever want the same data, start there instead.

Rack and power planning

Each drawer is physical: rack units, power feed and cabling. On a machine that supports four per node, a fully expanded configuration is a facilities question as much as a storage one.

NED24 drawer support is a property of the machine type, not the model family. The S1112 supports no NED24 at all and is limited to its 4 internal slots plus half a Gen4 I/O expansion drawer when rack-mounted. If an entry system needs real flash growth, that constraint usually decides the machine type rather than the other way around.

Related

Per-model storage ceilings are on the Power 11 specs page, and the drawer listing is at NED24 NVMe expansion drawer. For the shared-storage comparison see FlashSystem external storage for Power 11. The short definition is at NED24 in the glossary.